Labeler Troubleshooting

Field Service

Labeler Troubleshooting

Symptom Possible Cause Solution
Label heads are not turning on Label heads are not engaged properly. Reposition label head to engage the product surface as it passes the peeler plate
Position the first label so that it extends past the peeler plate giving it a “flag” to allow the product to catch the label as it passes
Check power to labeler; provide necessary power
Check webbing for proper installation. Refer to your Operations Manual as well as to the label web path guide, check web path to ensure proper label stock positioning
Safety cover not engaged. Ensure the safety cover is fully engaged